Experimental Study on PBL Shear Connectors of Steel-Concrete Composite Bridge Considering Transverse Prestressing
-
摘要: 为研究钢-混组合梁桥PBL剪力键的抗剪承载能力及其影响因素,以兰州小砂沟大桥为工程背景,设计3类13组共33个试件,采用推出试验的方法进行试验研究,对比分析了PBL剪力键的破坏形态、破坏机理以及抗剪承载能力的影响因素,提出了考虑横向预应力效应的PBL剪力键抗剪承载能力的计算公式.研究结果表明:贯穿钢筋直径、钢板开孔孔径以及钢板厚度的增加均能有效提高PBL剪力键的抗剪承载能力;横向预拉应力的存在促进了混凝土的开裂,使得混凝土、钢板及贯穿钢筋的强度和刚度无法得到充分发挥,从而降低了PBL剪力键的承载能力,对单孔抗剪承载能力降低可达10%;横向预压应力的约束作用延缓了混凝土的开裂,使得混凝土、钢板及贯穿钢筋的强度和刚度得到充分发挥,提高了PBL剪力键的承载能力,对单孔抗剪承载能力提高可达20%;考虑横向预应力效应的公式计算结果与试验结果吻合较好.Abstract: In order to study the shear capacity and its influencing factors of PBL shear connectors for steel-concrete composite girder bridges, 33 specimens in 13 groups of three types were designed for push-out tests conducted in Xiaoshagou Bridge in Lanzhou, China. The failure modes, failure mechanisms, and influencing factors of shear capacity of these PBL shear connectors were analyzed comparatively. On this basis, a shear capacity calculation formula for PBL shear connectors considering the transverse prestressing effect was proposed. The results show that the shear capacity of PBL shear connectors could be effectively increased by increase of transverse rebar diameter, perforated rib diameter, and perforated rib thickness. The existence of transverse pretension stress accelerated the cracking of concrete, causing the strength and stiffness of concrete, perforated plate, and reinforcing rebars unable to exert their effect fully. As a result, the shear capacity of PBL shear connectors were reduced by about 10%. In addition, the constraint effect of transverse stress improved the strength and stiffness of concrete and delayed the concrete cracking, bringing the strength and stiffness of concrete, perforated plate, and reinforcing rebars into full play, and resulting in an significant improvement (20%) in the shear capacity of PBL shear connectors. The calculated results from the proposed formula close to the test results verified its effectiveness.
-
Key words:
- composite bridges /
- push-out test /
- shear connectors /
- shear capacity
-
AHN J H, LEE C G, WON J H, et al. Shear resistance of the perfobond-rib shear connector depending on concrete strength and rib arrangement[J]. Journal of Constructional Steel Research, 2010, 66(10):1295-1307. OGUEJIOFOR E C, HOSAIN M U. A parametric study of perfobond rib shear connectors[J]. Canadian Journal of Civil Engineering, 1994, 21(4):614-625. 胡建华,侯文崎,叶梅新. PBL剪力键承载力影响因素和计算公式研究[J]. 铁道科学与工程学报,2007,4(6):12-18.HU Jianhua, HOU Wenqi, YE Meixin. Study of influence factors and formula for the bearing capacity of PBL shear connectors[J]. Journal of Railway Science and Engineering, 2007, 4(6):12-18. 宗周红,车惠民. 剪力连接件静载和疲劳试验研究[J]. 福州大学学报:自然科学版,1999,27(6):61-66.ZONG Zhouhong, CHE Huimin. Experimental study of shear connector under static and fatigue loading[J]. Journal of Fuzhou University:Natural Science, 1999, 27(6):61-66. 赵灿晖,夏嵩,李乔. PBL剪力连接器的承载机理与屈服荷载[J]. 西南交通大学学报,2014,49(4):605-611.ZHAO Canhui, XIA Song, LI Qiao. Load-bearing mechanism and yield load of PBL shear connectors[J]. Journal of Southwest Jiaotong University, 2014, 49(4):605-611. COST-NEVES L F, FIGUEIREDO J P, VELLASCO P C G S, et al. Perforated shear connectors on composite girders under monotonic loading:an experimental approach[J]. Engineering Structures, 2013, 56:721-737. VALENTE I, CRUZ P J S. Experimental analysis of perfobond shear connection between steel and lightweight concrete[J]. Journal of Constructional Steel Research, 2004, 60(3/4/5):465-479. KIM S H, AHN J H, CHOI K T, et al. Experimental evaluation of the shear resistance of corrugated perfobond rib shear connections[J].Advances in Structural Engineering, 2011, 14(2):249-264. OGUEJIOFOR E C, HOSAIN M U. Numerical analysis of push-out specimens with perfobond rib connectors[J]. Computer Structures, 1997, 62(4):617-624. USHIJIMA Y, HOSAKA T, MITSUKI K, et al. An experimental study on shear characteristics of perfobond strip and its rational strength equations[C]//Proceedings of the International Symposium on Connections between Steel and Concrete. Stuttgart:University of Stuttgart, 2001:1066-1075. HOSAKA T, MITSUKI K, HIRAGI H, et al. An experimental study on shear characteristics of perfobond strip and its rational strength equations[J]. Journal of the Structural Engineering, 2000, 46A:1593-1604. MEDBERRY S B, SHAHROOZ B U. Perfobond shear connectors for composite construction[J]. Engineering Journal, 2002, 39(1):2-12. AI-DARZI S Y K, CHEN A R, LUI Y Q. Finite element simulation and parametric studies of perfobond rib connector[J]. American Journal of Applied Sciences, 2007, 4(3):122-127. VERISSIMO G S, PAES J L R, VALENTE I, et al. Design and experimental analysis of a new shear connector for steel and concrete composite structures[C]//Proceedings on the 3rd International Conference on Bridge Maintenance, Safety, Management, Life-Cycle Performance and Cost (IABMAS 2006). Porto:Taylor and Francis/Balkema, 2006:807-809. 袁国干,杨健. 预应力混凝土连续梁抗剪强度研究[J]. 中国公路学报,1999,12(3):49-56.YUAN Guogan, YANG Jian. Study of shearing strength of P.C. continuous beams[J]. China Journal of Highway and Transport, 1999, 12(3):49-56.
点击查看大图
计量
- 文章访问数: 581
- HTML全文浏览量: 91
- PDF下载量: 254
- 被引次数: 0