Design of Photoacoustic Imaging System with High Positioning Accuracy Based on PCI4732
-
摘要: 为了研究光声成像技术对不同吸收体的成像性能,利用PCI4732和高精度旋转台RT-5-10,在Labview软件设计平台上开发了一套光声成像系统.系统由脉冲激光器、水浸探头和放大器等硬件组成,采集卡通过PCI总线与电脑连接.采用高分辨率滤波反投影重建算法对数据进行处理,得到较高对比度和分辨率的图像.分别采用2.25、5.00和10.00 MHz的超声探头对发丝进行试验,以验证系统的实用性.试验结果显示:采用5.00 MHz的探头比采用2.25和10.00 MHz的探头得到的发丝的图像更清晰,表明对于一定尺寸的吸收体,需要选择一定中心频率的探头,才能得到清晰的图像.Abstract: In order to research the photoacoustic imaging abilities of different absorbers, a photoacoustic imaging system was developed based on Labview software design platform coupled with PCI4732 and high positioning accuracy rotation stage RT-5-10. This system consists of a pulsed laser, an immersion probe and an amplifier and so on, and a PCI (peripheral component interconnect) bus was used to realize the connection between the PCI card and a computer. A high resolution filtered back-projection reconstruction algorithm was used to process the data and obtained high contrast and high resolution images. To verify the practicability of the developed system it was tested using human hairs as objects respectively with 2.25, 5.00 and 10.00 MHz transducers. The result indicates that a 5 MHz transducer can gain clearer images than a 2.25 or 10 MHz transducer to show that certain absorber should correspond to certain frequency of transducer.
-
Key words:
- high positioning accuracy /
- ultrasonic probe /
- photoacoustic imaging technology /
- resolution /
- PCI4732
-
陈湛旭,唐志列,万巍. 基于声透镜系统的光声层析成像[J.] 物理学报,2006,55(8): 4365-4369. CHEN Zhanxu, TANG Zhilie, WAN Wei. Photoacoustic tomography imaging based on an acousticlens imaging system[J]. Acta Physica Sinica, 2006, 55(8): 4365-4369. [2] TAN Yi, XING Da, WANG Yi. Photoacoustic imaging with attenuation rectification of different frequent components of photoacoustic signal[C]∥Proc.of SPIE's 50th Annual Meeting: Optics Photonics. San Diego: The International Society for Optical Engineering, 2005, 5630: 668-674. [3] 傅健,路宏年. 基于平板探测器的2D-CT成像技术的研究[J. 光学技术,2005,31(5): 662-665. FU Jian, LU Hongnian. Research on 2D-CT imaging technique based on flat panel detector[J]. Optical Technique, 2005, 31(5): 662-665. ]]]]] [4] 孙创伟,忽满利,高爱华,等. 基于成像光谱仪的频域OCT的实验研究[J]. 光电工程,2009,36(9): 76-81. SUN Chuangwei, HU Manli, GAO Aihua, et al. Frequency-domain OCT based on the imaging spectrometer[J]. Opto-Electronic Engineering, 2009, 36(9): 76-81. [5] WANG L V. Tutorial on photoacoustic microscopy and computed tomography[J]. IEEE Jourmal of Selected Topics in Quantum Electronics, 2008, 14(1): 171-179. [6] ORAEVSKY A A, WANG L V. Photons plus ultrasound: Imaging and sensing[C]∥Proc.of SPIE's 8th Conference on Biomedical Thermoacoustics, Optoacoustics, and Acousto-optics. Bellingham: SPIE, 2007, 6730: 451-466. [7] LI L, ZHANG H F, ZEMP R J, et al. Simultaneous imaging of a lacZ-marked tumor and microvasculature morphology in vivo by dual-wavelength photoacoustic microscopy[J]. Journal of Innovative Optical Health Sciences, 2008, 1(2): 207-215. [8] ATLAN M, FORGET B C, BOCCARA A C, et al. Cortical blood flow assessment with frequency-domain laser Doppler microscopy[J]. Journal of Biomedical Optics, 2007, 12(2): 024019-1-024019-8. [9] WANG Yimin, BOWER B A, IZATT J A, et al. In vivo total retinal blood flow measurement by Fourier domain Doppler optical coherence tomography[J]. Journal of Biomedical Optics, 2007, 12(4): 041215-1-041215-8. [10] ZHANG C, MASLOV K, WANG L V. Subwavelength-resolution label-free photoacoustic microscopy of optical absorption in vivo[J]. Optics Letters, 2010, 35(19): 3195-3197. [11] 安琪,李芾,傅茂海. 牵引电机振动对构架疲劳强度的影响[J]. 西南交通大学学报,2010,45(2): 209-212. AN Qi, LI Fu, FU Maohai. Influences of traction motor vibration on bogie frame fatigue strength[J]. Journal of Southwest Jiaotong University, 2010, 45(2): 209-212. [12] 蒋林,肖建,王涛. 感应电机的Takagi-Sugeno型模糊状态观测器[J]. 西南交通大学学报,2010,45(2): 273-277. JIANG Lin, XIAO Jian, WANG Tao. Takagi-Sugeno fuzzy state observer for induction motor[J]. Journal of Southwest Jiaotong University, 2010, 45(2): 273-277. [13] Newmark Systems Inc. Software Reference of RT-5-10[CD/DB]. Newmark Systems Inc., 2010. [14] Quantel French. User's manual brilliant B V5.3[M]. [S.l.]: Quantel French, 2008: chapter4-1-chapter4-5. [15] 龙华伟,顾永刚. LabVIEW 8.2.1与DAQ数据采集[M]. 北京:清华大学出版社,2008: 127-313. [16] ZHANG H F, MASLOV K, LI M L. In vivo volumetric imaging of subcutaneous microvasculature by photoacoustic microscopy[J]. Optics Express, 2006, 14(20): 9317-9323. [17] CHEN Z X, TANG Z L, WAN W. Photoacoustic tomography imaging based on a 4f acoustic lens imaging system[J]. Optics Express, 2007, 15(8): 4966-4976.
点击查看大图
计量
- 文章访问数: 1204
- HTML全文浏览量: 63
- PDF下载量: 412
- 被引次数: 0