• ISSN 0258-2724
  • CN 51-1277/U
  • EI Compendex
  • Scopus
  • Indexed by Core Journals of China, Chinese S&T Journal Citation Reports
  • Chinese S&T Journal Citation Reports
  • Chinese Science Citation Database
Volume 20 Issue 2
Apr.  2007
Turn off MathJax
Article Contents
ZHANG Yong, QIANG Hua, HAO Jing, HUANG Nan, DU Quanxing. Width Error Analysis of Stent Strut and Optimization of Laser Cutting Procedure[J]. Journal of Southwest Jiaotong University, 2007, 20(2): 229-233.
Citation: ZHANG Yong, QIANG Hua, HAO Jing, HUANG Nan, DU Quanxing. Width Error Analysis of Stent Strut and Optimization of Laser Cutting Procedure[J]. Journal of Southwest Jiaotong University, 2007, 20(2): 229-233.

Width Error Analysis of Stent Strut and Optimization of Laser Cutting Procedure

  • Received Date: 07 Jul 2006
  • Publish Date: 25 Apr 2007
  • To solve the problem of uneven strut widths of stents cut by laser, laser cutting procedure test was conducted, and the motion of the tube was analyzed.The results show that the deviation of the strut width is mainly caused by the variation in laser defocus and that in the tangent velocity at the cutting point.The procedure parameters were optimized according to the above analysis.The strut widths of the stent cut with the optimized procedure vary within 0.010 mm, conforming to the design specifications, when the eccentricity of tube at cutting point is within 0.030 mm and the defocus is-0.05 mm.

     

  • loading
  • 王先逵.精密加工技术实用手册[M].北京:机械工业出版社,2001:352.[2] 王涛.古桂茹.李玉祥,等.激光在机械制造技术中的应用[J].激光杂志,2006,27(3):75-76.WANG Tao,GU Guiru,LI Yuxiang,et al.Application of laser in the technology of mechanical nanufacture[J].Laser Journal,2006,27(3):75-76.[3] ETAVE F,FINET G,MAURICE B,et al.Mechanical properties of cornary stent deternined by using finite element analysis[J].Journal of Biomechanics,2001,34:1 065-1 070.[4] 杨杰,黄楠,杜全兴,等.描述血管支架力学性性能的新概念——形状系数[J].生物医学工程学杂志,2006,(1):74-77.YANG Jie,HUANG Nan,DU Quanxing,et al.Shape coefficient-A new concept to describe the vascular stent mechanical property[J].Journal of Biomedical Engineering,2006,(1):74-77.[5] ROGERS C,TSENG D Y,SQUIRE J C,et al.Balloon-artery interactions during stent placement:a finite element analysis approach to pressure,compliance,and stent design as contributors to vascular injury[J].Circ.Res.,1999,84(4):378-385.[6] 张康年.激光加工技术[M].北京:化学工业出版社,2004:38.[7] MCGARRY J P,O DONNELL B P,MCHUGH P E,et al.Analysis of the mechanical performance of a cardiovascular stent design based on micromechanical modeling[J].Computation Materials Science,2004,31:421-438.