The transient responses of voltage regulator (VR) to sudden load changes and the
parameters of aVR affecting the transient response of output voltage were analyzed to achieve a VR
with fast transient responses. The analyses show that using a low equivalent series resistance (ESR)
capacitorwith a carefully determined value and raising switching frequency can decrease outputvoltage
fal.l Simulation results verify thatdecreasing the inductance of the inductor reduces the outputvoltage
fall and response time by about 20% and 60%, respectively; selecting a capacitorwith the critical
capacitance reduces the outputvoltage fallby about40%, but increases response time; and compared
with voltagemode contro,l currentmode control reduces the output voltage fall and response time by
about20% and 70%, respectively.