Based on the basic formula of the limit load-bearing capacity of reinforced concrete (RC)
columns strengthened with prestressed struts, the relationship between momentMand axial loadN
of a strengthened column is analyzed theoretically, and itsM-Ndiagram is obtained. By comparing
with theM-Ndiagram of a common RC column, the result shows that this strengthed method has a
reasonal range of application.