Determination of Nitrite in Water with Flow Injection Chemiluminescence Method

  • Publish Date: 25 Aug 2003
  • A new chemiluminescence method for the determination of nitrite in water is presented. This method is based on nitrite reaction with hydrogen dioxide solution with catalyst acid to create peroxynitrous acid. Peroxynitrous acid reacts with alkaline solution of luminol, producing chemiluminescence. The linear range for nitrite is 3.3×10-3to 3.3μg/mL with a detection limit of 1.6×10-3μg/mL, and the relative standard detection is 1.03% for 0.17μg/mL NO-2and 4.38% for 0.017μg/mL NO-2. This method has obtained satisfactory results in the analysis of natural waters.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views(1317) PDF downloads(203) Cited by()