• ISSN 0258-2724
  • CN 51-1277/U
  • EI Compendex
  • Scopus
  • Indexed by Core Journals of China, Chinese S&T Journal Citation Reports
  • Chinese S&T Journal Citation Reports
  • Chinese Science Citation Database
Volume 27 Issue 3
May  2014
Turn off MathJax
Article Contents
LI Donghui, ZHANG Jundong, JI Yulong. Stability Research for Parallel Operation of Diesel Generator Sets[J]. Journal of Southwest Jiaotong University, 2014, 27(3): 494-498. doi: 10.3969/j.issn.0258-2724.2014.03.019
Citation: LI Donghui, ZHANG Jundong, JI Yulong. Stability Research for Parallel Operation of Diesel Generator Sets[J]. Journal of Southwest Jiaotong University, 2014, 27(3): 494-498. doi: 10.3969/j.issn.0258-2724.2014.03.019

Stability Research for Parallel Operation of Diesel Generator Sets

doi: 10.3969/j.issn.0258-2724.2014.03.019
  • Received Date: 13 Sep 2011
  • Publish Date: 25 Jun 2014
  • In order to analyze quantitatively the stability of parallel operation of diesel generator sets and monitor the state of generators being out of step during development of a simulator for the ship power system, calculation formulae for parameters of the swing angle were deduced. An on-line algorithm for calculating the parameters of swing curves of generators was presented, and the parametric exponents of the curve were calculated by solving high-order state differential equations. In addition, the stability degree of parallel operation (SDPO) was defined, and the Simulink tool box was used to set up a simulation system to verify the algorithm. The results of simulation examples show that the SDPO can indicate the stability allowance of parallel operation of diesel generator sets. The parameters obtained by the algorithm can reflect the stability of parallel operation in real time during the simulator training. The parameters of the swing curve can be determined by differentiation of the curve from the first to the forth order. When the exponents change with time or the data of the curve are discrete, the parametric exponent can be obtained by derivation using the five-point interpolation method.

     

  • loading
  • 段远才, 金松令. 柴油发电机并联运行与调整[M]. 北京:国防工业出版社, 1988: 123-127.
    GAWANDE S P, PORATE K B, RAISONI G H. Review of parallel operation of synchronous generator and induction generator for stability[C]//Proceedings of the 2nd International Conference on Emerging Trends in Engineering and Technology. Nagpur: IEEE Press, 2009: 716-721.
    BASLER M J, SCHAEFER R C. Understanding power system stability[J]. IEEE Transactions on Industry Applications, 2008, 44(2): 463-474.
    KUANG Honghai, ZHU Wenhui. Transient stability of multi-machine wind turbine generators system connected to the gird[C]//Proceedings of the International Conference on Energy and Environment Technology. Guilin: IEEE Press, 2009: 917-921.
    TRUDNOWSKI D J, GEBTILE A, KHAN J M, et al. Fixed-speed wind-generator and wind-park modeling for transient stability studies[J]. IEEE Transactions on Power Systems, 2004, 19(4): 911-917.
    叶运骅. 小型同步发电机组并联运行稳定性的探讨[J]. 合肥工业大学学报:自然科学版, 2002, 25(5):753-757. YE Yunhua. Analysis of the stability of small synchro generator sets operating in parallel[J]. Journal of Hefei University of Technology: Natural Science, 2002, 25(5): 753-757.
    QI L. AC system stability analysis and assessment for shipboard power system[D]. College Station: A&M University, 2004.
    ABD-EI-REHIM M A, HELAL I D, OMAR M A H. Multi-machine power system dynamic equivalents using artificial intelligence (ANN)[C]//Proceedings of the 11st International Middle East Power Systems Conference. EI-MInia: IEEE Press, 2006: 197-207.
    LU Fang, YU Jilai. Using critical machine couple equal area criterion to assess multi-machine system stability[C]//Proceedings of Asia-Pacific Power and Energy Engineering Conference. Wuhan: IEEE Press, 2009: 1-4.
    BOUDOUR M, HELLAL A. Self-organizing feature maps for power system dynamic security assessment using synchronizing and damping torques technique[C]//Proceedings of the 29th Annual Conference of the IEEE. Roanoke: IEEE Press, 2003: 752-757.
    WANG Zhenhua, ADLY G, VISVAKUMAR A, et al. Wide area power system transient stability assessment using catastrophe theory method and synchrophasors[C]//Proceedings of Power and Energy Society General Meeting. Detroit: IEEE Press, 2011: 1-7.
    JAEWOOK L. An optimization-driven framework for the computation of the controlling UEP in transient stability analysis[J]. IEEE Transactions on Automatic Control, 2004, 49(l): 115-119.
    杨青, 马伟明, 刘德志, 等. 3/3相双绕组发电机系统的并联运行稳定性[J]. 中国电机工程学报, 2005, 25(1): 97-103. YANG Qing, MA Weiming, LIU Dezhi, et al. Stability of paralleled 3/3 phase double winding generators with simultaneous AC and rectified DC load[J]. Proceedings of the CSEE, 2005, 25(1): 97-103.
    GLOVER J D, SARMA M S. Power system analysis and design[M]. Beijing: China Machine Press, 2004: 613-616.
    高景德, 王祥珩, 李发海. 交流电机及其系统的分析[M]. 北京:清华大学出版社, 2005: 186-192.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views(1104) PDF downloads(476) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return